beautypg.com

Ivoclar Vivadent Vectris User Manual

Page 18

background image

18

P R E PA R AT I O N G U I D E L I N E S A N D M I N I M U M

R E Q U I R E M E N T S F O R V E C T R I S F R A M E W O R K S

As Vectris restorations are luted in place using an adhesive cementation method, a tooth-conserving

preparation technique can be used.

Anterior crowns and bridge abutments

Evenly reduce the anatomical shape and observe the stipulated minimum thickness. Prepare a 360°

shoulder with rounded inner edges or a deep chamfer of at least 0.8 mm. For anterior crowns, the labial

and/or palatal/lingual surfaces should be reduced by at least 1.0 mm. Reduce the incisal crown third by at

least 1.5 mm. Prepare smooth, rounded transitions so that no internal line angles or edges are present.

0.8

0.8

1

1

1.5

Posterior crowns and bridge abutments

Evenly reduce the anatomical shape and observe the stipulated minimum thickness. Prepare a 360° shoulder

with rounded inner edges or a deep chamfer. For posterior crowns, reduce the labial and/or palatal/lingual

surfaces by at least 1.0 mm. Reduce the occlusal crown third of posterior teeth by at least 1.5 mm. Prepare

smooth, rounded transitions so that no internal line angles or edges are present.

1.5

1.5

1.5

1

1

0.8

0.8