Layer thicknesses
Observing the geometry requirements of the Telio CAD structure is the key to success for a durable restoration. The more
attention is given to the design, the better the final results and the clinical success will turn out to be.
The following basic guidelines have to be observed:
Minimum thicknesses
–
occlusal: min.
1.5
mm
–
circular: min.
0.8
mm
– Telio CAD A16 in the transition area to the Ti base rim:
min. 0.5 mm
– The notes of the implant manufacturer regarding the maximum height of the hybrid abutment crown must be observed.
– In the transition area to the Ti base rim, the minimum thickness is 0.5 mm, which has to be continuously increased to
0.8 mm.
Block selection
When using a Ti base from Sirona, the dimensions of the interface to the Ti Base (S or L) have to be observed.
Available tooth shades Telio CAD A16 block with S or L interface:
LT A1, LT A2, LT A3, LT A3.5, LT B1, LT BL3
> 0.5 mm
> 0.8 mm
Hybrid abutment crown
Telio
®
CAD Abutment Solutions
– Fabricating a T
elio CAD Hybrid Abutment Cr
own
> 1.5 mm