beautypg.com

Ivoclar Vivadent Telio CAD A16 User Manual

Page 15

background image

15

Do not blast the Telio CAD structure.

Thinly apply SR Connect with a disposable brush.

Do not disperse.

Light-cure for 40 s.

Preparing the Telio CAD structure

The following procedure must be observed when preparing the Telio CAD structure for cementation on the Ti base:
– Do not blast the Telio CAD structure in preparation for the cementation.
– Clean the Telio CAD structure in an ultrasonic bath or with the steam jet and subsequently blow dry.
– After cleaning, any contamination of the bonding surface must be prevented, since contaminations negatively influence

the bond.

– Thinly coat the bonding surface with SR Connect using a disposable brush and allow to react for 30 s. Subsequently,

polymerize with a polymerization light (e.g. Bluephase Style) for 40 s.

Device

Bluephase

®

Style

(Polywave

®

, 1100 ± 10% mW/cm

2

)

Manufacturer

Ivoclar Vivadent AG

SR Connect

40 s

Lumamat 100

Spectramat

Labolight LV-III

Solidilite V

Visio Beta Vario

HiLite Power

Ivoclar Vivadent

Ivoclar Vivadent

GC

Shofu

3M

Heraeus

P2: 11 min

2 min

3 min

3 min

4 x 20 s

90 s

Status 2014

Note:

The SR Connect reaction time of 30 s must be observed: If SR Connect is applied as a conditioner for Telio

CAD A16 for longer than that, the accuracy of fit may be compromised.

Telio

®

CAD Abutment Solutions

– Cementation of Ti Base / T

elio CAD Structur

e