Ivoclar Vivadent Telio CAD A16 User Manual
Page 15
15
Do not blast the Telio CAD structure.
Thinly apply SR Connect with a disposable brush.
Do not disperse.
Light-cure for 40 s.
Preparing the Telio CAD structure
The following procedure must be observed when preparing the Telio CAD structure for cementation on the Ti base:
– Do not blast the Telio CAD structure in preparation for the cementation.
– Clean the Telio CAD structure in an ultrasonic bath or with the steam jet and subsequently blow dry.
– After cleaning, any contamination of the bonding surface must be prevented, since contaminations negatively influence
the bond.
– Thinly coat the bonding surface with SR Connect using a disposable brush and allow to react for 30 s. Subsequently,
polymerize with a polymerization light (e.g. Bluephase Style) for 40 s.
Device
Bluephase
®
Style
(Polywave
®
, 1100 ± 10% mW/cm
2
)
Manufacturer
Ivoclar Vivadent AG
SR Connect
40 s
Lumamat 100
Spectramat
Labolight LV-III
Solidilite V
Visio Beta Vario
HiLite Power
Ivoclar Vivadent
Ivoclar Vivadent
GC
Shofu
3M
Heraeus
P2: 11 min
2 min
3 min
3 min
4 x 20 s
90 s
Status 2014
Note:
The SR Connect reaction time of 30 s must be observed: If SR Connect is applied as a conditioner for Telio
CAD A16 for longer than that, the accuracy of fit may be compromised.
Telio
®
CAD Abutment Solutions
– Cementation of Ti Base / T
elio CAD Structur
e