Finishing – Ivoclar Vivadent Telio CAD A16 User Manual
Page 10

10
Finishing
Conventional cross-cut tungsten carbide burs are suitable for finishing and adjusting the Telio CAD structure.
During finishing, make sure that the minimum layer thicknesses are observed. The milled Telio CAD structure is separated
from the block by means of a fine cross-cut bur or a diamond separating disc.
Checking the fit of the Telio CAD structures on the Ti base
Carefully place the CAD structures on the Ti base and check the fit. Observe the position of the rotation lock.
Finishing
Important!
– Do not finish the shoulder of the Telio CAD structure to prevent negatively affecting the Ti base.
– Finish the emergence profile if required taking the fit to the gingiva and the minimum thickness into account.
Finishing the outer surface of the Telio CAD structure (hybrid abutment crown)
– Smooth out the attachment point to the block with fine tungsten carbide burs taking the shape of the emergence profile
and the proximal contacts into account.
– Check the proximal, occlusal and basal contacts.
– Design surface textures.
Clean the Telio CAD structure in an ultrasounic bath or blast with the steam jet before further processing.
Separate the attachment point from the incisal using a fine, cross-cut bur or a
diamond separating disc.
Carefully place the Telio CAD structure on the Ti base and check the fit.
Optimum fit of the Telio CAD structure on the Ti base