Work table connection -22, Power supply #2 connection -22, Work table connection - pg. 3-22 – Hypertherm HT4400 HySpeed Plasma Arc Cutting System User Manual
Page 56: Power supply #2 connection – pg. 3-22, Work table connection, Power supply #2 connection, ቱcable - power supply to work table, ቲcable - power supply #1 to power supply #2
INSTALLATION
3-22
HT4400
Instruction Manual
Work Table Connection
ቱ
Cable - Power Supply to Work Table
Installation Notes
Pass the work cable through one of the 2"
bushings in the lower rear of the power
supply and connect to the upper bar (+) on
the center wall rear as shown on page 3-10.
Attach the other end to the work table.
Part No.
Length
123418
10 ft (3 m)
023382
15 ft (4.6 m)
023136
20 ft (6.1 m)
023078
25 ft (7.6 m)
023101
30 ft (9.2 m)
023135
40 ft (12.2 m)
023079
50 ft (15.3 m)
Part No.
Length
123316
60 ft (18.3 m)
023124
75 ft (22.9 m)
023080
100 ft (30.5 m)
123084
125 ft (38.1 m)
023081
150 ft (45.8 m)
123097
175 ft (53.4 m)
023188
200 ft (61 m)
Power Supply #2 Connection
ቲ
Cable - Power Supply #1 to Power Supply #2
Installation Notes
W
hen using a multi-torch system, the hold cable may be
used to interface the two power supplies. Make connec-
tions at TB3 on both supplies. TB3 is located on the
inside rear wall of the power supply. See figure below.
N
ote:
This feature can also be directly controlled by the
CNC.
ቲ
RUN LIST –
Power Supply #1 to
Power Supply #2
SIGNAL
PS#1
COLOR
PS#2
Hold Signal
86
Black
86
Hold Common
87
Red
87
Hold Shield
Gnd
Shield
Gnd
Part No.
Length
123591
10 ft (3 m)
023340
15 ft (4.5 m)
123592
20 ft (6.1 m)
023341
25 ft (7.5 m)
123593
30 ft (9.2 m)
Part No.
Length
123594
40 ft (12.2 m)
023342
50 ft (15.3 m)
023343
100 ft (30.5 m)
023344
150 ft (45.8 m)
Lower Frame of Work Table (typical)
(Logic +
12VDC,
close to
start)
Hold cable connections
ቱ
ቱ
2