Aluminum, English, Metric – Hypertherm HT4400 HySpeed Plasma Arc Cutting System User Manual
Page 189: Plasma / n, Shield 400 amps
e-8
HT4400
Instruction Manual
2
Aluminum
N
2
Plasma / N
2
Shield
400 Amps
120786
Retaining Cap
120856
Nozzle
120853
Swirl Ring
120855
Electrode
*
Piercing not recommended
Minimum inlet pressures remain at one setting of 140 psi (9.6 bar) for all material thicknesses.
Approximate pressures while cutting in RUN mode:
PG1
59
PG2
28
Flow Rates @ 140 psi / 9.6 bar
(scfh / slh)
N
2
Preflow
235.9 / 6680
Cutflow
237.7 / 6731
MV1 MV2 MV3 MV4 MV5
MV6 MV7 PG1 PG2 PG1 PG2
Inches
Volts
in.
mm
ipm
mm/m
in.
mm
seconds
1/4
135
.125
3
220
5588
.250
6
0.3
3/8
140
.125
3
195
4953
.250
6
0.5
1/2
145
.157
4
150
3810
.314
8
0.7
5/8
150
.157
4
105
2667
.314
8
1
3/4
155
.188
5
80
2032
.375
10
1.5
7/8
160
.188
5
65
1651
.375
10
2
1
165
.188
5
50
1270
.375
10
2.5
1-1/4
170
.250
6
40
1016
*
*
*
1-1/2
180
.250
6
30
762
*
*
*
2
185
.250
6
15
381
*
*
*
English
Test Preflow and Cutflow Adjust (psi)
Test
Preflow
Verify (psi)
Test
Cutflow
Verify (psi)
Initial Pierce
Height
Pierce
Delay
Time
Plasma
Shield
Plasma
Shield
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
60
43
35
40
0
0
0
34
36
49
30
MV1 MV2 MV3 MV4 MV5
MV6 MV7 PG1 PG2 PG1 PG2
mm
Volts
mm
in.
mm/m
ipm
mm
in.
seconds
6
135
3
.125
5914
233
6
.250
0.3
10
140
3
.125
4718
186
6
.250
0.5
12
145
4
.157
4032
159
8
.314
0.7
15
150
4
.157
2968
117
8
.314
1
20
155
5
.188
1935
76
10
.375
1.5
22
160
5
.188
1668
66
10
.375
2
25
165
5
.188
1290
51
10
.375
2.5
30
170
6
.250
1085
43
*
*
*
40
180
6
.250
709
28
*
*
*
50
185
6
.250
405
16
*
*
*
Metric
Test Preflow and Cutflow Adjust (psi)
Test
Preflow
Verify (psi)
Test
Cutflow
Verify (psi)
Initial Pierce
Height
Pierce
Delay
Time
Plasma
Shield
Plasma
Shield
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
60
43
35
40
0
0
0
34
36
49
30