Gas regulators – Hypertherm HT4400 HySpeed Plasma Arc Cutting System User Manual
Page 179
APPENDIX C – GAS REGULATORS
c-2
HYPERTHERM Plasma Systems
2.1
Gas Regulators
Low-quality gas regulators do not provide consistent supply pressures and can result in poor cut quality and system
operation problems. Use a high-quality, 1-stage, gas regulator to maintain consistent gas supply pressure, if using
liquid cryogenic or bulk storage. Use a high-quality, 2-stage, gas regulator to maintain consistent gas supply
pressure from high pressure gas cylinders.
The high-quality gas regulators listed below are available from Hypertherm and meet U.S. Compressed Gas
Association (CGA) specifications.
In other countries, select gas regulators that conform to national or local codes.
Part
Number
Description
Qty.
128544
Kit: Oxygen, 2-Stage *
1
128545
Kit: Inert Gas, 2-Stage
1
128546
Kit: Hydrogen (H5, H35 and Methane) 2-Stage
1
128547
Kit: Air, 2 Stage
1
128548
Kit: 1 Stage (For use with cryogenic liquid Nitrogen or Oxygen)
1
022037
Oxygen, 2-Stage
1
022038
Inert Gas, 2-Stage
1
022039
Hydrogen/Methane, 2-Stage
3
022040
Air, 2-Stage
1
022041
Line Regulator, 1-Stage
1
* Kits include appropriate fittings
2-Stage Regulator
1-Stage Regulator