Machine interface connections - 2 of 2 -21, Machine interface connections - 2 of 2, ተcable - machine i/o interface to power supply – Hypertherm HT4400 HySpeed Plasma Arc Cutting System User Manual
Page 55: Warning

INSTALLATION
HT4400
Instruction Manual
3-21
2
Machine Interface Connections - 2 of 2
ተ
Cable - Machine I/O Interface to
Power Supply
Installation Notes
If using the Command THC, do not connect this cable.
ተ
RUN LIST –
Machine I/O Interface t
Power Supply Cable
SIGNAL
Terminal
COLOR 1X6
Remote OFF**
78
Green
32
Remote ON**
79
Red
37
Remote ON/OFF Shield**
Cut
Shield
26
Hold Signal (12VDC) Signal. Closed-ON;Open=OFF
87
White
1
Hold Common
86
Black
5
Hold Shield
Cut
Shield
10
Plasma Start (12VDC) Signal. Closed=Start
82
Blue
9
Plasma Start Signal
83
Black
15
Plasma Start Shield
Cut
Shield
14
Plasma Emergency Stop (24VAC) Signal. Closed=Stop 80
Yellow
28
Plasma Emergency Stop Signal
81
Red
33
Plasma Emergency Stop Shield
Cut
Shield
27
Arc Xfer Output - Signal. Dry contact relay†*
84
Red
36
Arc Transfer Output - Signal*
85
Blue
31
Arc Transfer Output - Shield*
Cut
Shield
25
Pierce Complete***
135
Orange
4
Pierce Complete***
136
Black
8
Pierce Complete Shield***
Cut
Shield
13
Error Counter
167
Green
35
Error Counter
168
Black
30
Error Counter Shield
Cut
Shield
24
Notes:
* Contact closes after arc transfer and time delay
** To enable a remote ON/OFF switch, the jumper on TB4 must be moved from
terminals 1&2 to terminals 2&3 - see figure.
*** A contact closure will activate pierce complete and keeps shield in preflow
mode. Open the contacts for shield cutflow mode.
Note on the µP PCB that resistor R150 and capacitor C78 are connected in
series across the contacts. In some cases, one lead of R150 must be cut from
the control PC board, as the R-C circuit may provide enough current flow to
maintain machine motion input to the cutting machine.
1X6
Part No.
Length
123574
10 ft (3 m)
123575
15 ft (4.6 m)
123576
20 ft (6.1 m)
023892
25 ft (7.6 m)
123577
30 ft (9.2 m)
123578
40 ft (12.2 m)
023893
50 ft (15.3 m)
Part No.
Length
123579
60 ft (18.3 m)
023894
75 ft (22.9 m)
023895
100 ft (30.5 m)
123089
125 ft (38.1 m)
023896
150 ft (45.8 m)
123033
175 ft (53.4 m)
023897
200 ft (61 m)
(Logic +
12VDC,
close to
start)
**Move jumper to TB4
terminals 2&3 to enable
a remote ON/OFF switch
WARNING
W
hen installing or servicing the HT4400, AC or DC line voltages may be present on the
TRANSFER signals even if the power supply line disconnect switch is OFF. Make certain that
all line disconnect switches relating to the HT4400 system are OFF during installation and when
servicing.