beautypg.com

Serial i/o board pcb5 - status indicators -24, Serial i/o board pcb5 - status indicators – Hypertherm HT4400 HySpeed Plasma Arc Cutting System User Manual

Page 115

background image

MAINTENANCE

5-24

HT4400

Instruction Manual

3

Serial I/O Board PCB5 - Status Indicators

The Serial I/O Board interfaces with the gas console and the microprocessor control board. The serial board
controls all outputs for the gas console. When an LED on LEDN1 or LEDN2 is illuminated, the corresponding
output or input is active. See page 6-2 for location of Serial I/O Board.

Note:

D2 needs to be illuminated for the outputs to be active.

If D5 is illuminated and D2 is not, then there is a communication problem between the
microprocessor control board (PCB2) and the serial board (PCB5).

LEDN1-5 through LEDN1-8 illuminate when in proper working conditions (no errors).

LEDN1-10

Not used

LEDN1-9

Not used

LEDN1-8

Shield cut-flow pressure switch (SC)

LEDN1-7

Plasma cut-flow pressure switch (PC)

LEDN1-6

Shield preflow pressure switch (SP)

LEDN1-5

Plasma preflow pressure switch (PP)

LEDN1-4

BCD1

LEDN1-3

BCD2

LEDN1-2

BCD4

LEDN1-1

BCD8

LEDN1
Input light bar

D2
Outputs Enabled

D5
+12 VDC

LEDN2
Output light bar

LEDN2-10

Not used

LEDN2-9

Not used

LEDN2-8

Nitrogen purge valve (SV-NP)

LEDN2-7

Secondary gas shield preflow (SV7)

LEDN2-6

Secondary gas shield cut-flow (SV6)

LEDN2-5

Secondary gas preflow (SV5)

LEDN2-4

Primary gas shield preflow (SV4)

LEDN2-3

Primary gas shield cut-flow (SV3)

LEDN2-2

Primary gas preflow (SV2)

LEDN2-1

Plasma cut-flow (SV1)

LEDN1

LEDN2

J2

P1

J1

J3