Sdi led display, Sdi unit status, Sdi run time code – Gasboy SDI CAT Interface User Manual
Page 14: Equipment provided

SC II and CFN3
SDI/Wayne CAT Interface
7
Gasboy CFN Series
SDI LED Display
The SDI unit has a single LED located next to the switch assembly. This LED is used to display
the status of the SDI unit and the Wayne CAT units. The LED display consists of a series of
blinks and delays that show the site status. SDI unit status is shown using a slow or fast blinking
LED with no delay between blinks. SDI run time status is shown by a series of 1 to 4 blinks in a
group followed by a delay between groups. The display codes are:
SDI Unit Status
Slow steady blink
SDI unit is ready; but needs application loaded
Fast blink
SDI unit has problems; Call your service representative
SDI Run Time Code
Equipment provided
- This documentation
- SDI Box
- SDI power supply w/ AC power cable
- Interface cable for the Wayne CAT’s w/ two wires marked plus and minus.
- Disk with Wayne CAT software
Number of Blinks
Status (with delay between group)
1
Site down; all CAT’s down
2
Site up; all CAT’s down
3
Site down; some CAT’s up
4
Site up; some CAT’s up (normal operation)