Graphic sequences, Sdi box switches – Gasboy SDI CAT Interface User Manual
Page 13

6
SDI/Wayne CAT Interface
SC II and CFN3
Gasboy CFN Series
Graphic Sequences
The SDI is capable of several graphic sequences. The graphic CAT comes embedded supporting
the following:
~B = spinning clock
~P = pumping
~C = insert card
~R = receipt printing
~G = press grade
~S = press START
~L = remove nozzle lift lever
~W = want car wash?
~N = remove nozzle
SCII version 2.3 and above or CNF3 version 3.0B and above support graphics. Car wash is
supported only on CFN3.
Example
Graphic sequences are entered into the READER program. To display an insert card graphic,
place a ~C in the Insert Card step as illustrated below. To insert spinning clock while the
customer’s card is being verified, insert a ~B into the Verify Card step. The words will display on
the top of the screen with the graphic under the words.
SDI Box Switches
The SDI box contains a switch for setting the SDI box number and for clearing the unit’s
memory. Switch functions are:
MODA/MODB are on switch 7, RESET on switch 8.
For Wayne CAT, SDI #1, make all switches to OFF (open).
For Wayne CAT, SDI #2, make position 5 ON (closed), all others OFF (open).
To clear application memory:
(Do this under instruction from qualified support engineer only)
1.
Close switch position 6
2.
Close switch position 8
3.
Open switch position 8
4.
Wait a few seconds
5.
Open switch position 6
# Ty S/D DISPLAY WHILE ENTERING OPTIONS
1 1 ! INSERT CARD~C ! !
2 3 6 ! ENTER YOUR PIN !YOUR PIN ! Optional Auto-enter Masked
3 7 7 ! ENTER ODOMETER !ODOMETER ! Optional
4 2 2 ! SELECT PUMP NUMBER !SELECT PUMP !
5 9 !Verifying Card...~B ! !
6 10 ! ! !
7 16 2 ! [PRODUCT] ! !
8 19 2 !PUMP #XX IS READY ! !
9 13 2 ! We Thank You ! !
10 !--------END---------! !
1
2
3
4
5
6
7
8
ADDR ADDR
ADDR
ADDR
ADDR
DLD
MODA
RESET
4
3
2
1
0
MODB