beautypg.com

System setup, System parameters (sys_par) – Gasboy EDS-CCIS Credit User Manual

Page 8

background image

2

EDS/CCIS

Credit & Debit Card Networks

Gasboy CFN Series

System Setup

System Parameters (SYS_PAR)

This information is provided for reference only. The menu programs initialize and/or stores the appropriate
values for you in the system parameters.

Reader verification - page 4

Use remote verification (reader): Credit

Use local verification (reader): Club

Check mod 10 (reader): None

Check expiration date (reader): Credit (and optionally club)

Console verification - page 5

Use remote verification (reader): Credit

Use local verification (reader): Club

Check mod 10 (reader): None

Check expiration date (reader): Credit (and optionally club)

Serial port configuration - Page 8

Host handler channel: The number of the port used for communicating with the network. This is the same

port you connected to the modem.

Host router data: Use for your EDS/CCIS truck stop number.

More router data: Two-digit price level to use for refrigerated-trailer-fuel transactions.

Host Handler Baud Rate: The communications baud rate received from your EDS/CCIS representative.

Send requests to host handler: Credit

Host handler data: Two two-digit numbers; the default numbers are 00 and 20. Enter the numbers by typing:

00

20

(Repeat

as needed to exit host handler data.)

The first two digits are 00 if your modem is a Hayes 1200, 01 if your modem is a Hayes 2400, and
02 if it is a Hayes Optima.

The second two-digit number is a hexadecimal value for the number of seconds to allow for the
carrier to be received. The default 20 sets it for 32 seconds. Setting it for 10 would make it 16
seconds, 18 would be 24 seconds, 28 would be 40 seconds, and 30 would be 48 seconds.

Transaction miscellany - page 11

Verification timeout: 0 seconds (no timeout).

ENTER

ENTER

ENTER

ENTER