beautypg.com

Gasboy Q Series User Manual

Page 2

background image

020897 Rev. 06/12/03

Page 2

4. Behind the junction box, disconnect the existing vent tube and

remove the existing compression elbow in the pumping unit.
Install a 3/8” inverted flared fitting (item 9) into the pumping unit
where the compression elbow just been removed. Rotate the
new fitting at about 35

°

as shown in Figure 3.

Figure 3

5. Install the pre-assembled unit from Step 3 onto the underside of

the motor/pump platform. Using a ¼-20 x ½ Taptite screw
(item 8, feed through an existing hole in the platform that is
close to the flange and the left side column. Secure the unit
loosely. (Figure 4)

Figure 4

6. Connect the vent tube assembly with flared nuts (item 3)

between the pumping unit’s elbow and the bottom elbow of the
sump overflow assembly (item 1). (Figure 5: NOTE: Junction
box removed for visibility.
)

Figure 5