Reference

Remedy

Possible cause

Symptom

-

Connect the system
to the mains.

System not
connected to mains.

The system cannot
be started after
switching on.

-

Replace fuse below
power switch.

Fuse is blown.

-

Close the covers.

A cover is opened.

Loading Envelopes

on page 17

Check envelope feed
adjustments. Place
envelopes correctly in
hopper.

Envelopes stacked
reversed in the
hopper.

System stops with
envelope at insert
position (flap not
open).

Envelope settings

on page 38

Store envelopes
according to
specifications.

Envelope flap sticks.

Envelope settings

on page 38

Change envelopes
according to
specifications.

Wrong envelope type
used (not according
to specifications or
job settings).

Loading Envelopes

on page 17

Adjust envelope
separation.

Envelope separation
not correctly set.

Envelopes are double
fed.

Loading Envelopes

on page 17

Check and replace if
needed.

Envelopes not placed
properly in the
hopper.

Loading Envelopes

on page 17

Check side guides
and adjust if needed.

Side guides of the
envelope hopper are
set too wide.

Envelope stops
skewed.

Loading Envelopes

on page 17

Refill hopper.

Hopper almost empty.

Envelopes are fed
irregularly.

Loading Envelopes

on page 17

Adjust envelope
separation.

Separation set too
narrow.

Loading Envelopes

on page 17

Check side guides
and adjust if needed.

Side guides set too
narrow.

Loading Envelopes

on page 17

Reposition the
envelope support.

Envelope support not
positioned correctly.

68