Brake Horse Power at Best Efficiency
Point.
dBA
3 to 14 Stages
90 to 110
79
110 to 140
80
140 to 180
81
180 to 220
82
220 to 280
83
280 to 360
84
360 to 450
85
450 to 560
86
560 to 720
87
720 to 900
88
900 to 1125
89
1125 to 1400
90
1400 to 1800
91
1800 to 2250
92
2250 to 2800
93
2800 to 3600
94
3600 to 4500
95
4500 to 5700
96
5700 to 7200
97
7200 to 9000
98
9000 to 11,000
99
11,000 to 14,000
100
1.9.3
Combined noise levels for pump and
driver components
When two or more sources produce noises that are
sufficiently unrelated (so that interference effects do
not occur) the total combined noise level may be
obtained by a simple addition of dB values according
to the below table.
Difference between two
levels to be Combined, dB
Add to higher level to
obtain Combined level, dB
0
3
1
2.5
2
2
4
1.5
6
1
9
0.5
10
0