DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09

Page 21 of 60

operation may require the full coupling misalignment
capability.

4.4.1.1

Types of misalignment

There are two types of shaft misalignment: Angular
and offset. Both types of misalignment can occur in
horizontal and vertical planes and are present in most
applications.

In angular misalignment, the centerline of the shafts
intersects, but is not on the same axis.

Angular misalignment

In offset misalignment, the shaft centerlines are
parallel but do not intersect.

Offset misalignment

Combined misalignment



4.4.1.2

Alignment methods

The following methods may be used to align
equipment train. The methods a) and b) are dial
indicator based.

a) Rim and face alignment

Rim and face alignment

b) Reverse rim indicator alignment

Reverse rim indicator alignment


c) Laser alignment.

4.4.2

Dial-indicator-based alignment

4.4.2.1

Check soft foot

Soft foot can affect the alignment readings and
should be checked first and eliminated on both pump
and driver.

a) Tighten hold down bolts.

b) Set a dial indicator on one foot, loosen the bolt

and check if there is a indicator reading. If so
place a shim with the same thickness as the
displacement.

c) Check and adjust all feet.

PUMP SIDE

DRIVER SIDE

PUMP SIDE

DRIVER SIDE