Flowserve DMX User Manual
Page 35

DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Page 35 of 60
6.2 Spare parts
6.2.1
Ordering of spares
Flowserve keep records of all pumps that have been
supplied. When ordering spares the following
information should be quoted:
•
Pump serial number
•
Pump size/type
•
Order number
•
Part name – taken from section 8 or pump
sectional drawing
•
Part number – taken from section 8 or pump
sectional drawing
•
Number of parts required – taken from
section 8 or pump sectional drawing
The pump size and serial number are shown on the
pump nameplate.
Order number should be taken from 10.4 Customer
Data sheet.
For 24-Hour part ordering service, call Flowserve
Distribution Center at +1 800 526 3569.
To place an order, contact the nearest Flowserve
office found at www.flowserve.com.
The use of parts other than Flowserve
approved parts may create hazardous conditions
over which Flowserve has no control. Such
hazardous conditions can lead to injury, or result
in damage to the equipment. Flowserve does not
support nor will be responsible for the use of non
Flowserve furnished parts nor the use of
materials that are not as originally furnished
without the expressed written approval of
Flowserve.
6.2.2
Service instructions
For 24-hour emergency repair service, contact the
Flowserve Service Department at +
1 800 547
8671
or +1 908 859 7372 or contact the nearest
Flowserve Service Center.
6.2.3
Storage of spares
Spares should be stored in a clean dry area away
from vibration. Inspection and re-treatment of
metallic surfaces (if necessary) with preservative is
recommended at 6 monthly intervals.
6.3 Recommended spares and
consumable items
A recommended spare parts classification is offered
for Flowserve parts furnished on this unit. The
classification of a required part can be identified by
referring to the appropriate assembly drawing and
parts list included in section 8 of this manual.
The recommended spare parts are divided into three
classifications, which are defined below.
a) CLASS 1 (Minimum): Covers recommended
spare parts for a single unit where additional
spare parts are ordinarily available from
branch or dealer stock. Suggested for
Domestic Service handling non-corrosive
liquids where interruptions in service are not
objectionable. This include gaskets and
bearings that are not reusable.
b) CLASS 2 (Average): Covers recommended
spare parts for a single unit where additional
spare parts are not readily available.
Suggested for Domestic Service handling
abrasive or corrosive liquids where some
interruptions in service are permissible. This
includes Class 1 spares plus all renewable
wear parts.
c) CLASS 3 (Maximum): Covers recommended
spare parts for a single unit where maximum
protection from major shutdown must be
considered. Suggested for Export Service or
Domestic Service where minimum loss of
service is essential. This includes Class 1 &
2 spares plus a spare rotating assembly.
The Flowserve Sales Representative in your area will
gladly review the class of spares best suited to your
requirement.
6.4 Tools required
No special tools are required to assemble
or disassemble the pump. Common mechanical
tools are sufficient. However we recommend torque
wrench to tighten and remove all fasteners.
6.5 Fastener torques
6.5.1
Torque values
The torque values are given for each stud size for
both standard casing and high pressure casing with a
cross reference to hydro-pressures.