Connecting a boiler
without thermostat
input

If the boiler does not have a
thermostat input, you can
directly control the circulator
located next to the boiler.

To control electric
convectors, you MUST use
a power contact switch that
is suitable for the total power
to be controlled.

N

L

circulator

power supply

230V/50Hz

230V

contact switch (not
supplied) fitted in the
electrical switchboard

N

N

L

L

convector(s)

mains supply

230V/50Hz

power supply of the

contact switch coil

230V

convector(s)

N

OR

direct convector

control if power

< 3000 W

Connection to the heating

- 8 -

Connecting a boiler with thermostat input

Connect receiver terminals 3 and
4 to both terminals of the boiler
thermostat input.

If necessary, remove the shunt (electric wire)
connecting the two
thermostat input
terminals.

If the boiler has a clock
input, do not mistake it
for the thermostat input.

boiler
thermostat
input

boiler

230V

remove

the shunt

wires to be

connected to

the receiver

Example of a boiler

terminal box

do not mistake for

the clock input

(on some boiler