Delta Dore 827 W RF TYBOX User Manual
2 sec

• Carefully read these instructions prior to use.
• Do not attempt to repair the unit yourself;
an after-sales service is available.
TYBOX 827 RF
From the RUN mode, override enables:
- for the heating, modification of the temperature
setting (5°C to 30°C) until the next programme
change
- for the hot water, modification of the current
operation (ON/OFF) until the next programme
change
Press a button to “activate” the display.
On the receiver:
- the green LED indicates that the product is
switched on,
- the red LED indicates the status of the output(s):
light on = ON, light off = OFF.
MAN Mode
ONCE Mode
• Override is only accessible in AUTO or ONCE
mode.
• To cancel an active override, press the relevant
button (
or
) or turn the dial.
• These instructions apply to both the TYBOX 817 WRF
and the TYBOX 827 WRF.
• The hot water mode (
) is only available on the
TYBOX 827 WRF.
1. Presentation
4. Override
5. Information button
3. Choosing the operating mode
6. Date / Time
7. Programming the heating
2. RUN Mode
Time
Heating
and
hot water
modes
Room
temperature
Override
buttons
General mode active
Override
currently active
Information
button
5°C
30°C
6.00
AM
16°C
16°C
20°C
20°C
20°C
18°C
18°C
8.00
AM
11.00
AM
1.00
PM
5.00
PM
11.00
PM
12.00
AM
Period
1
2
3
4
5
6
6.00
AM
16°C
16°C
20°C
20°C
18°C
18°C
8.00
AM
11.00
AM
1.00
PM
5.00
PM
11.00
PM
12.00
AM
Period
1
2
3
4
5
6
MON
SUN
Period
1 6
HH:MM
5°C
30°C
Copy MON ... TUE ...
> 2 sec.
> 2 sec.
Stand-by
screen:
• Room
temperature
• Current day
and time
Change mode
buttons
Selector dial
TYBOX 827 RF
TYBOX 817- 827 W RF
1 and 2-channel wireless programmers
with built-in thermostat
User guide
Delta Dore hereby declares that the equipment complies
with the essential requirements and other relevant provisions
of the R&TTE Directive 1999/5/EC.
The EC declaration of conformity for this equipment is available,
on request, from:
“Technical info” department
DELTA DORE - Bonnemain - 35270 Combourg (France)
Email: [email protected]
Because of changes in standards and equipment, the characteristics given in the
text and the illustrations in this document are not binding unless confirmed.
*2702541_rev.2*
4
1
2
3
DD.MM.YY
PM
AM
12.00
(00.00)
11.59
(23.59)
1
MAN
Constant
temperature setting
NA
OFF
Frost Protection
Off
AUTO
Follows the programming
ONCE
Follows the ONCE programme.
Return to AUTO mode at the end of the
countdown.
ON
NA
Permanent ON
Select the mode
by pressing
or
repeatedly.
Turn the dial to exit the
setting mode.
5°C
30°C
30°C
5°C
30°C
5°C
PERM
365
001
Heating
Hot water
Automatic exit after 30 seconds
if no buttons are pressed and
the dial is not turned.
ONCE mode
end day
Configuration
Time setting
MODE
Operating mode
selection
RUN
Run the operating
mode selected
Absence mode
CH
Heating
programming
HW
Hot water
programming
Example: default programme applied from
Monday to Friday:
The programme can be changed for each day.
Periods 2 to 5 can be disabled.
For example, disabling the midday slot
(periods 3 and 4).
To copy the
programming from one
day to the next day.
To return to the program, press the
R
button
again and hold for 2 seconds.
A simplified programme can be applied
(2 programmable periods) for a set number of days
(ONCE mode).
Current date and
number of days before
service.
Hot water channel status
until ...
Heating channel
status until ...
R
: back to previous
setting
R
: back to previous
setting
R
: back to previous
setting
R
: back to previous
setting
Please not that you can’t define hot water
temperature in this programmer
2702541_rev2(not_util_TYBOX827_WRF)_EN_vect:Mise en page 1 04/07/2011 12:11 Page 1