oid = "1.3.6.1.2.1.2.2.1.9.ifIndex"
ifLastChange: The value of sysUpTime at the time the interface entered its current
operational state
Access: read-only
oid = "1.3.6.1.2.1.2.2.1.10.ifIndex"
ifInOctets: the total number of octets received on the interface, 32 bit
Access: read-only
oid = "1.3.6.1.2.1.2.2.1.11.ifIndex"
ifInUcastPkts: The number of unicast packets received, 32 bit
Access: read-only
oid = "1.3.6.1.2.1.2.2.1.12.ifIndex"
ifInNUcastPkts: The number of non-unicast packets received, 32 bit
Access: read-only
oid = "1.3.6.1.2.1.2.2.1.13.ifIndex"
ifInDiscards: The number of inbound packets discarded with no error detected, 32 bit
Access: read-only
oid = "1.3.6.1.2.1.2.2.1.14.ifIndex"
ifInErrors: The number of inbound packets with errors, 32 bit
Access: read-only
oid = "1.3.6.1.2.1.2.2.1.15.ifIndex"
ifInUnknowProtos: The number of packets received via the interface which were
discarded because of unknown or unsupported protocol. Returns 0.
Access: read-only
oid = "1.3.6.1.2.1.2.2.1.16.ifIndex"
ifOutOctets: The total number of packets transmitted, 32 bit
Access: read-only
oid = "1.3.6.1.2.1.2.2.1.17.ifIndex"
ifOutUcastPkts: The number of packets transmitted to a unicast address, 32 bit
Access: read-only
oid = "1.3.6.1.2.1.2.2.1.18.ifIndex"
ifOutNUcastPkts: The number of packets transmitted to a non-unicast address, 32 bit
Access: read-only
oid = "1.3.6.1.2.1.2.2.1.19.ifIndex"
ifOutDiscards: The number of outbound packets discarded with no error detected, 32 bit
Access: read-only
oid = "1.3.6.1.2.1.2.2.1.20.ifIndex"
ifOutErrors: The number of outbound packets with errors, 32 bit
Access: read-only
oid = "1.3.6.1.2.1.2.2.1.22.ifIndex"
ifSpecific: A reference to MIB definition specific to the particular media being used to
realize the interface
Access: read-only