Vipersat Configuration

3-24

Vipersat CDM-570/570L User Guide

Figure 3-25 Entry Channel Switch Rates screen

Entering the Remote number at the command prompt in figure 3-25 allows the

SCPC Data Rate and the Switch Type for that Remote to be set, as shown in

figure 3-26. Switch type 0 corresponds to Load Switching; switch types 64

through 255 are user-defined, and must match VMS policies. When choosing

Load Switching as the Switch Type, the associated Remote must have the Load

Switching feature Enabled (see the section “STDMA/SCPC Automatic Switch-

ing” on page 3-31).

Figure 3-26 Remote SCPC Data Rate and Switch Type prompt

The Global SCPC Rate command can be used to set the data rate for all or a

majority of the Remotes. This allows the rate to be entered just once instead of

entering the rate for each remote individually. Enter G at the command prompt.

Figure 3-27 Global SCPC Data Rate prompt