Factory default settings – menu options, Factory default settings – network settings – Cloud Electronics DCM1 User Manual
Page 71

DCM1 & DCM1e Installation and User Guide v1.0
71
Factory default settings – menu
options
The table below lists the default factory settings for all
DCM1 menu options. These are the settings which the unit
will assume on power-up if Power Up Mode is set to
Factory
.
The factory default key for enabling Installer Mode is included
in the list at System Mode > Set Key.
MUSIC MENU:
Select Input
Input 1 routed to all Zones; no other
assignments
Level
All Zones at minimum (muted)
Treble
0 dB
Mid
0 dB
Bass
0 dB
Input Gain
All Inputs 0 dB
Maximum Music Level
All Zones 0 dB (max.)
Minimum Music Level
All Zones -62 dB (muted, min.)
ROUTING MENU:
Enable Mic Inputs
No Mics assigned to any Zone
Input Enable
All Inputs available in all Zones
Configure Access Connector
Input
CDPM Zone Offset
0
CDR Zone Offset
0
SYSTEM MENU:
CDR Zone Setup
All Zones OFF
Stereo/Mono Zone Selection
Zones 1 and 2 stereo
Rename Inputs
Input 1 to Input 8
Rename Zones
Zone 1 to 8
Rename Groups
Groups 1 to 4
Set Key
1234
RS232 Baud Rate
9600
RS232 Flow Control
OFF
Power Up Mode
Factory
Save Defaults
n/a
Update Firmware
OFF
Reset Mixer
n/a
PRIORITIES MENU:
Select Priority Line Input
No Input assigned to any Zone
Line Priority Hold Time
3 sec.
Line Priority Release Time
1 sec.
Set Mic Priority Input
No Input assigned to any Zone.
Mic Priority Hold Time
3 sec.
Mic Priority Release Time
1 sec.
Mic Priority Attenuation
30 dB
Page Priority Select
Off
Page Priority Hold Time
3 secs.
Page Priority Release Time
1 sec.
Page Priority Attenuation
30 dB
Select Emergency Source
No Input assigned
Emergency Level
Maximum
Configure Music Mute
Normally Open (N/O)
GROUPS MENU:
Group Enable
No Groups enabled
Group Member
No Groups defined
Note that restoring the factory default settings (either by
setting Power Up Mode to Factory, or by moving
jumper J9) does not overwrite any Input, Zone or Group
names that have been assigned.
Factory default settings – network
settings
The following network settings are applicable to the DCM1e
only:
Network Item
Setting
IP Address
DHCP enabled
NETBIOS Name
DCM1-ANON
MAC Address
00:04:A3:xx:xx:xx
00:1E:C0:xx:xx:xx