- D 95 -

Short Seam Automat 2211-5 Working Instructions

Beisler Automated Sewing Equipment

D.3

Programming

D.3.13 Level 2 special parameters / Lists

Parameter setting for level 2 submenus
The following section describes the special parameters that
are set in lists. When a submenu is requested, only tho-
se positions of the parameter list are displayed that refer
to the machine function.

Move to a line in the list:

Press

" or # key.

Special parameter menu

% 0=1?Z

F1

Back to start level

F3

Select start modes list

F4

Open upper part parameters list

F5

Open stitch lengths and bar tacks list

F6

Open parameter list for clamp transport

F7

Open assistance transport list

„

„

„

„

„ Selecting start modes:
Two modes can be set in this menu:

Start mode,

Blowing mode.

0

Press

key.

Change parameters:

Press

$ key.

Insert new value using numeric keypad or

Press

. or Y key.

Confirm input:

Press

W key.

Settable values:

Start mode
The selected start mode determines how the machine
operation is started and executed. Four modes are availa-
ble:

Mode 04

Mode 05

Mode 06

Mode 07

The individual settings for machine operation are described
in Section B.3.10, Machine operation.

Blowing mode
When this mode is selected, the sewing piece is smoo-
thened after the sewing process before it is transported
to the stacker.

00, off

01, on, only parts blowing Y47

02, on, only slash selvage blowing Y46

03, on, eingeschaltet parts blowing Y47 and slash
selvage blowing Y46

„

„

„

„

„ Setting upper part parameters:
This list is used for setting all parameters for functions of
the sewing head.
The minimum and maximum values of input are limited
by the program control unit. Values that are not within the
limits will not be accepted but reduced to the correspon-
ding minimum or maximum value.

=

Press

key.

The parameter list is shown on the display.

NOTE - Sewing speed!

Possible settings for the sewing speed refer to the fol-
lowing sewing ranges:

Sewing speed 1 to the start distance,

sewing speed 2 to the center distance,

sewing speed 3 to the end of the seam.

The speed is set in increments of 100 rpm.