Functions of the machine – Beisler 2211-5 User Manual
Page 25
- B 25 -
Short Seam Automat 2211-5 Working Instructions
Beisler Automated Sewing Equipment
B.2
Functions of the machine
Fig. 19
Supply switches:
Main switch
The main switch 2 is used to turn the power supply
of the machine on or off. For safety reasons, the ma-
chine must be turned off using the main switch when
it is standing still for an extended period; in this case,
all functional units are deactivated. The main switch
also serves as an additional emergency off switch.
Vacuum switch
The vacuum switch 5 is used to turn the optional va-
cuum pump on and off.
Control switches:
Footswitch for machine operation
This footswitch 3 is used to control the individual ope-
rating steps of the machine or for starting the fully au-
tomatic machine operation.
Footswitch for slash selvage clamp
Depressing the footswitch for the slash selvage clamp
4 will open or close the slash selvage clamp indepen-
dently of the switching state.
B.2.16 Switches
The short seam automat is equipped with three different
types of switches:
•
Emergency switch for stopping a sewing program,
•
supply switch for voltage and vacuum pump,
•
control switches for controlling the machine operation.
Emergency switch:
Program stop key
When the program stop key 1 is pressed, all machine
movements and the sewing process are stopped im-
mediately.
The switch engages when pressed. Rotating the switch
in the clockwise direction will release the switch, and
it moves back into its original position.
The control program performs a reset.
Fig. 19