Short Seam Automat 2211-5 Working Instructions

- D 80 -

Beisler Automated Sewing Equipment

D.3

Programming

D.3.2 Service menu start level

The service functions of the service menu are requested
by direct access from the start level or from level 1. Ser-
vice functions support the working process during machine
production.

Functions on the start level
The function keys on the start level are assigned to the
symbols below them. These symbols cannot be changed;
they are always visible.

/ZP!

F1 Request service menu level 1
F2 Insertion distance length,

photocell correction for beginning of seam

F3 Change photocell correction for end of seam, seam

length and fixed seam end point

F5 Drive assistance transport to service position
F6 Actuate thread clamp manually
F7 Test cutters manually
F8 Reset insertion process

„

„

„

„

„ Requesting service menu level 1:
Direct access to the functions of the service menu on the
level 1.

Press

key.

„

„

„

„

„ Insertion distance length, photocell correction for

beginning of seam:

The settings control the beginning of the seam. They refer
to the currently selected seam and are in close relation
to the settings made using function F3 for the end of the
seam.
The menu offers two setting options:

The photocell response delay for the beginning of
the seam,

the setting of the insertion distance length at the
beginning of the seam

Photocell response delay:
To set the response delay of the photocell, the correspon-
ding function "Photocell for beginning of seam" must be
enabled (see Section D.3.9). The higher the input value,
the later the sewing process starts.

Insertion distance length:
If the function "Photocell for beginning of seam" is disabled,
the beginning of the seam is controlled by a fixed inser-
tion distance (see Section D.3.9). The insertion distance
is the distance that the main clamp moves toward the
sewing head before the sewing head starts sewing.
The setting refers to a correction of the insertion length
for the beginning of the seam. The higher the input value,
the longer the insertion distance.

Enter value:

Press

key.

/

The cursor automatically marks the variable value.
To change this value gradually:

Press

. or Y key.

Enter a completely new numeric value:

Enter numbers using numeric keypad.

Confirm input and exit menu:

Press

W key.

NOTE - Checking settings!

The settings must be checked using a sewing piece; if re-
quired, they must be corrected.