Programming – Beisler 2111-4 User Manual
Page 77
![background image](https://www.manualsdir.com/files/775198/content/doc077.png)
- D 77 -
Short Seam Automat 2110-4 / 2111-4 Workinging Instructions
Beisler Automated Sewing Equipment
D.3
Programming
D.3.4 Global parameters
No.
Programmable global parameters (F2)
01
TILL CLAMP SIDEWAYS FWD:
After clam p backward, tim e until clam p m oves s ideways to folder / tim e interval
02
TILL CLAMP DOWN ......:
After clam p forward s ideways to piece pick-up, tim e until clam p down / tim e interval
03
TILL VACUUM OFF ......:
After clam p down, tim e until vacuum is s witched off / tim e interval
04
THRD LENGTH,BOBBIN FULL
Length of thread of filled bobbin
05
TILL CLAMP INSERTING:
Clam p ins ertion delay / tim e delay
06
SEWING END ->CL.SIDEW.:
After s ewing drive s tops , tim e until clam p m oves s ideways / tim e interval
07
TIME AFTER CLAMP OPEN :
After clam p s ideways , tim e until clam p opens / tim e interval
For m achines with s afety s witch:
After clam p rearward s ideways and ES5 s witches , tim e until clam p opens / tim e interval
10
TILL FOLDING CL. CLOSED:
After folder right and down, tim e until folding clam p clos es
11
TILL FOLDER LIFT UP...:
After folding clam p clos es , tim e until folder up / tim e interval
12
TILL FOLDER SWINGS LEFT:
After folder up, tim e until folder s wings left and rotates / tim e interval
13
IMPULS FOLDER DOWN ...:
Puls e duration folder down, tim e until folder is s witched airles s during pick-up / tim e delay
14
CL.OPEN TILL FOLDER UP:
After folding clam p opens , tim e until folder up / tim e interval
17
TILL TENSION OPEN ....:
After end of s eam , tim e until tens ion blower on / tim e interval
18
DURATION OF TENS. OPEN:
ON duration for tens ion blower
19
TILL THREAD CLAMP FORW.:
After clam p up, tim e until thread clam p forward / tim e interval
20
DUR.THREAD CLAMP FORW.:
Duration of blowing and thread clam p forward
21
TILL STACKER TRANSPORT:
After s ewing drive s tops and trans port s tam p down, tim e until s tacker trans port m oves backward to ES8 / tim e
interval
22
DUR.SLIDING TABLE OPEN:
Duration for s liding table open / tim e delay
23
LIFT.TABLE MOD 00/01-99:
Lower lift table, defaults :
Input 00: Lower lift table us ing photocell control
Input 01-99: Lift table is lowered after corres ponding num ber of pieces
24
DUR.LIFTING TABLE SINKS:
Lower lift table / duration
25
TILL FABRIC CLAMP FORW.:
After foots witch is releas ed, tim e until pocket bag clam p clos es / tim e interval