Start-up – Beisler 2111-4 User Manual
Page 32
Short Seam Automat 2110-4 / 2111-4 Working Instructions
- C 32 -
Beisler Automated Sewing Equipment
C.3
Start-up
C.3.2 Compressed air connections
The compressed air connection is preinstalled on the
machine. It comprises the following components:
•
Pressure reducer
2 with manometer 4 and water
separator
5,
•
Pressure hose with push-in plug
1.
The pressure reducer is installed at the side mounting wall
of the worktable.
Connecting the machine to the compressed air sup-
ply system:
1. Connect pressure hose plug to on-site terminal unit.
2. Open on-site compressed air supply.
3. Set pressure reducer to a machine operating pressure
of 6 bar by rotating pressure reducer knob
3 and read
value on manometer
4:
• To increase pressure, rotate in clockwise direction.
• To reduce pressure, rotate in counter-clockwise di-
rection.
Fig. 3
Fig. 3
5
4
2
2
1
3