beautypg.com

Drive technology – BECKHOFF AM3000 User Manual

Page 35

background image

Drive Technology

9 Commissioning

AM3000 / AM3500

Version: 1.5

35

Fault

Possible cause

Measures to remove the cause

of the fault

Motor doesn’t rotate

Servo drive not enabled

Break in setpoint lead

Motor phases in wrong

sequence

Brake not released

Drive is mechanically blocked

Supply ENABLE signal

Check setpoint lead

Correct the phase sequence

Check brake control

Check mechanism

Motor runs away

Motor phases in wrong

sequence

Correct the phase sequence

Motor oscillates

Break in the shielding of the

feedback cable

Amplification to high

Replace feedback cable

Use motor default values

Error message: brake

Short-circuit in the supply

voltage lead to the motor

holding brake

Faulty motor holding brake

Remove the short circuit

Replace motor

Error message: output stage

fault

Motor cable has short circuit or

earth leakage

Motor has short circuit or earth

leakage

Replace motor cable

Replace motor

Error message: feedback

Connector is not properly

plugged in

Break in cable, cable crushed

or similar

Check connector

Check cables

Error message: motor

temperature

Motor thermostat has switched

Loose connector or break in

cable

Wait until the motor has

cooled down. Then investigate

why the motor becomes so

hot.

Check connector, replace

cable if necessary

Brake does not grip

Required holding torque too

high

Brake faulty

Check the dimensioning

Replace motor