2 ax2000 and ax2500, Drive technology – BECKHOFF AM3000 User Manual
Page 26

8 Electrical installation
Drive Technology
26
Version: 1.5
AM3000 / AM3500
Colour code for signal
pairs
8 pairs
1
st
pair
brown and white
2
nd
pair
green and yellow
3
rd
pair
grey and pink
4
th
pair
red and blue
5
th
pair
black and violet
6
th
pair
grey/pink and red/blue
7
th
pair
white/green and brown/green
8
th
pair
white/yellow and yellow/brown
Electrical specifications
Test conditions
20 °C
Test voltage
(conductor/conductor -
conductor/shielding)
Requirement
1500 VDC
undamaged insulation
Operating voltage
≤ 30 V
Conductor material
Conductor resistance
2 x 0.5 mm², tinned copper 19 x 0.18 mm
≤ 40 Ohm / km
Insulation resistance
min. 2500 MOhm x km
Capacitance:
Power
Signals
max. 100 pF / m
max. 120 pF / m
8.2.2 AX2000 and AX2500
All cables are specified for flexible routing. They enable highly dynamic operation and are UL-listed.
Motor cable with signal line
Specification
AX2000
4 x 1.5 mm
2
+ 2 x 1 mm
2
AX2500
4 x 1 mm
2
+ 2 x 1 mm
2
General data
Min. bending radius
118 mm
115 mm
Weight
185 kg / km
155 kg / km
Overall diameter
10.6 mm ± 4 %
10 mm ± 4 %
Max. velocity
120 m / min
Max. acceleration
4 m / s
2
Max. no. of cycles
10 million
Max. tensile load
static / dynamic
50 / 20 N / mm
2
Operating temperature
0 to 80 °C
Oil resistance
“VDE 0472 Part 803 B”; “VDE 0282 Part 10”;
“UL 1581”
Sheath
Material
PUR according to the UL standard
Shielding
tinned copper braid, optical cover ≥ 85%
Colour
RAL 2003 (orange)
Power leads
4 x 1.5 mm
2
4 x 1 mm
2
Conductor material
blank copper (DIN EN 60228; VDE 0295; IEC
60228)
Insulation
polyolefin polymer according to the
UL standard
Signal leads
2 x 1 mm
2
Conductor material
blank copper (DIN EN 60228; VDE 0295; IEC
60228)
Insulation
polyolefin polymer according to the
UL standard
Shielding
tinned copper sheath, optical cover ≥ 85%
Electrical specifications