Drive technology – BECKHOFF AM3000 User Manual
Page 23

Drive Technology
8 Electrical installation
AM3000 / AM3500
Version: 1.5
23
1
st
pair
black and black (5-6)
2
nd
pair
black and black (7-8)
Electrical specifications
Test conditions
20 °C
Test voltage for power
leads
(conductor/conductor -
conductor/shielding)
Test voltage for signal
leads
(conductor/conductor -
conductor/shielding)
Requirement
4 kV eff. 5 min.
2 kV eff. 1 min.
undamaged insulation
Operating voltage
≤1000 V
Conductor resistance
IEC 60228 Cl.5
Insulation resistance
≥2500 MOhm x km
Capacitance:
Power
Signals
max. 150 pF / m
max. 100 pF / m
Encoder cable
Specification
Encoder cable
7x(2x0.14mm
2
)+1x(2x0.5mm
2
)
Reserved
General data
Weight
kg / km
Min. bending radius
137 mm
Overall diameter
7.6 mm +/- 0.3 mm
Max. velocity
180 m / min
Max. acceleration
5 m / s
2
Max. no. of cycles
50.000
Max. tensile load
20 N / mm
2
Operating temperature
-10 to 80 °C
Standards and features
UL AWM listed
80 °C – 30 V
CSA AWM listed
75 °C – 30 V
Flame resistance
DIN EN 50265-2-1
Oil resistance
UL 1581
Silicone-free
yes
CFC-free
yes
Halogen-free
no
Sheath
Material
PVC according to UL AWM & CSA AWM
Shielding
tinned copper braid, optical cover ≥ 85%
Separator
Polyester strap
Colour
RAL 6018 (green)
Signal leads
7 x (2 x 0.14 mm
2
)
Conductor material
Conductor resistance
tinned copper 7x0.16 mm
≤140 Ohm / km
Insulation
polypropylene compliant with UL AWM & CSA AWM
Structure
pair-wise twisted
Colour code for signal
pairs
8 pairs
1
st
pair
brown and white
2
nd
pair
green and yellow
3
rd
pair
grey and pink
4
th
pair
red and blue
5
th
pair
black and violet