8 Electrical installation

Drive Technology

22

Version: 1.5

AM3000 / AM3500

8.2

Connection of motors with pre-assembled cables

Beckhoff offers preassembled motor and feedback cables for safe, faster and flawless installation of the

motors. Beckhoff cables have been tested with regard to the materials, shielding and connectors used. They

ensure proper functioning and compliance with statutory regulations such as EMC, UL etc. The use of other

cables may lead to unexpected interference and invalidate the warranty.

Carry out the wiring in accordance with the valid standards and regulations.

Only use our preassembled shielded cables for the power and feedback connections.

Connect up the shielding according to the wiring diagrams in sections 8.3 to 8.6. Incorrectly installed

shielding inevitably leads to EMC interference.

All available cable types are listed below. Should you require additional information please contact our support.

8.2.1 AX5000

All cables are UL-listed.

8.2.1.1 Cables for fixed installation
Motor cable with signal line

Specification

4 x 1.5 mm

2

+ 2 x (2 x 0.75 mm

2

)

General data

Weight

kg / km

Min. bending radius

203 mm

Overall diameter

11.3 mm +/- 4%

Max. velocity

180 m/min

Max. acceleration

5 m/s

2

Max. no. of cycles

50.000

Max. tensile load

20 N/mm

2

Operating temperature

-10 to 80 °C

Standards and features

UL AWM listed

80 °C – 1000 V

CSA AWM listed

75 °C – 1000 V

VDE (U

0

/ U)

0.6/1 kV

Flame resistance

DIN EN 50265-2-1

Oil resistance

UL 1581

Silicone-free

yes

CFC-free

yes

Halogen-free

no

Sheath

Material

PVC according to UL AWM & CSA AWM

Shielding

tinned copper braid, optical cover ≥ 85%

Separator

Polyester strap

Colour

RAL 2003 (orange)

Power leads

4 x 1.5 mm

2

Conductor material

blank copper cl.5 (DIN EN 60228; VDE 0295; IEC

60228)

Insulation

TEO Flexene ® polymer compound, compliant

with UL AWM & CSA AWM

Colour code

black (1 -3) + green/yellow

Signal leads

2 x (2 x 0.75 mm

2

)

Conductor material

blank copper cl. 5 (DIN EN 60228; VDE 0295; IEC

60228)

Insulation

TEO Flexene ® polymer compound, compliant

with UL AWM & CSA AWM

Structure

pair-wise twisted

Shielding per pair

tinned copper sheath, optical cover ≥ 85%

Separator

fleece tape

Colour code for signal pairs 2 pairs