2 connection of motors with pre-assembled cables, 1 ax5000, 1 cables for fixed installation – BECKHOFF AM3000 User Manual
Page 22: Drive technology

8 Electrical installation
Drive Technology
22
Version: 1.5
AM3000 / AM3500
8.2
Connection of motors with pre-assembled cables
Beckhoff offers preassembled motor and feedback cables for safe, faster and flawless installation of the
motors. Beckhoff cables have been tested with regard to the materials, shielding and connectors used. They
ensure proper functioning and compliance with statutory regulations such as EMC, UL etc. The use of other
cables may lead to unexpected interference and invalidate the warranty.
•
Carry out the wiring in accordance with the valid standards and regulations.
•
Only use our preassembled shielded cables for the power and feedback connections.
•
Connect up the shielding according to the wiring diagrams in sections 8.3 to 8.6. Incorrectly installed
shielding inevitably leads to EMC interference.
All available cable types are listed below. Should you require additional information please contact our support.
8.2.1 AX5000
All cables are UL-listed.
8.2.1.1 Cables for fixed installation
Motor cable with signal line
Specification
4 x 1.5 mm
2
+ 2 x (2 x 0.75 mm
2
)
General data
Weight
kg / km
Min. bending radius
203 mm
Overall diameter
11.3 mm +/- 4%
Max. velocity
180 m/min
Max. acceleration
5 m/s
2
Max. no. of cycles
50.000
Max. tensile load
20 N/mm
2
Operating temperature
-10 to 80 °C
Standards and features
UL AWM listed
80 °C – 1000 V
CSA AWM listed
75 °C – 1000 V
VDE (U
0
/ U)
0.6/1 kV
Flame resistance
DIN EN 50265-2-1
Oil resistance
UL 1581
Silicone-free
yes
CFC-free
yes
Halogen-free
no
Sheath
Material
PVC according to UL AWM & CSA AWM
Shielding
tinned copper braid, optical cover ≥ 85%
Separator
Polyester strap
Colour
RAL 2003 (orange)
Power leads
4 x 1.5 mm
2
Conductor material
blank copper cl.5 (DIN EN 60228; VDE 0295; IEC
60228)
Insulation
TEO Flexene ® polymer compound, compliant
with UL AWM & CSA AWM
Colour code
black (1 -3) + green/yellow
Signal leads
2 x (2 x 0.75 mm
2
)
Conductor material
blank copper cl. 5 (DIN EN 60228; VDE 0295; IEC
60228)
Insulation
TEO Flexene ® polymer compound, compliant
with UL AWM & CSA AWM
Structure
pair-wise twisted
Shielding per pair
tinned copper sheath, optical cover ≥ 85%
Separator
fleece tape
Colour code for signal pairs 2 pairs