8 Electrical installation
AM3000 / AM3500
Version: 1.5
27
Test conditions
20 °C
Test voltage for power leads
(conductor/conductor -
conductor/shielding)
Test voltage for signal leads
(conductor/conductor -
conductor/shielding)
Test period
Requirement
3 kV eff.
1.5 kV
5 min.
undamaged insulation
Operating voltage
≤ 1000 V
Conductor resistance
Signal leads
20.5 Ohm / km
Shielding resistance
Signal leads
50 Ohm / km
Insulation resistance
Power leads
Signal leads
min. 5000 MOhm x km
min. 20 MOhm x km
Capacitance
Power leads
Signal leads
max. 120 pF / m
max. 150 pF / m
Encoder and resolver cable
Specification
Encoder cable
8 x 2 x 0.14 mm
2
Resolver cable
4 x 2 x 0.25 mm
2
General data
Weight
69 kg / km
80 kg / km
Min. bending radius
75 mm
Overall diameter
7.5 mm +/- 4%
Max. velocity
120 m / min
Max. acceleration
4 m / s
2
Max. no. of cycles
10 million
Max. tensile load
static / dynamic
50 / 20 N / mm
2
Operating temperature
0 to 80 °C
Oil resistance
“VDE 0472 Part 803 B”; “VDE 0282 Part 10”; “UL
1581”
Sheath
Material
PUR according to the UL standard
Shielding
tinned copper braid, optical cover ≥ 85%
Colour
RAL 6018 (green)
Signal leads
8 x 2 x 0.14 mm
2
4 x 2 x 0.25 mm
2
Conductor material
blank copper (DIN EN 60228; VDE 0295; IEC
60228)
Insulation
polyolefin polymer according to the
UL standard
Structure
pair-wise twisted
Colour code for signal pairs 8 pairs
4 pairs
1
st
pair
brown and white
2
nd
pair
green and yellow
3
rd
pair
grey and pink
4
th
pair
red and blue
5
th
pair
black and violet
---
6
th
pair
grey/pink and red/blue
---
7
th
pair
white/green and
brown/green
---
8
th
pair
white/yellow and
yellow/brown
---
Electrical specifications
Test conditions
20 °C