Drive technology – BECKHOFF AM3000 User Manual
Page 24

8 Electrical installation
Drive Technology
24
Version: 1.5
AM3000 / AM3500
6
th
pair
grey/pink and red/blue
7
th
pair
white/green and brown/green
8
th
pair
white/yellow and yellow/brown
Electrical specifications
Test conditions
20 °C
Test voltage
(conductor/conductor -
conductor/shielding)
Requirement
1500 VDC
undamaged insulation
Operating voltage
≤ 30 V
Conductor material
Conductor resistance
2 x 0.5 mm², tinned copper 19 x 0.18 mm
0.5 mm
2
≤ 40 Ohm / km
Insulation resistance
min. 2500 MOhm x km
Capacitance:
Power
Signals
max. 100 pF / m
max. 120 pF / m
8.2.1.2 Cables for flexible installation / highly dynamic operation
Motor cable with signal line
Specification
4 x 1.5 mm
2
+ 2 x (2 x 0.75 mm
2
)
General data
Weight
kg / km
Min. bending radius
85 mm
Overall diameter
12.2 mm
E 4mm
Max. velocity
240 m / min
Max. acceleration
30 m / s
2
Max. no. of cycles
10 million
max. horizontal length
20 m
max. vertical length
5 m
Max. tensile load
20 N / mm
2
Operating temperature
-10 to 80 °C
Standards and features
UL AWM listed
80 °C – 1000 V
CSA AWM listed
75 °C – 1000 V
VDE (U
0
/ U)
0.6 / 1 kV
Flame resistance
DIN EN 50265-2-1
Oil resistance
UL 1581
Silicone-free
yes
CFC-free
yes
Halogen-free
yes
Sheath
Material
TMPU, halogen-free, compliant with UL AWM &
CSA AWM
Shielding
tinned copper braid, optical cover ≥ 85%
Separator
Polyester strap
Colour
RAL 2003 (orange)
Power leads
4 x 1.5 mm
2
Conductor material
blank copper cl.5 (DIN EN 60228; VDE 0295; IEC
60228)
Insulation
TEO Flexene ® polymer compound, compliant
with UL AWM & CSA AWM
Colour code
black (1 -3) + green/yellow
Signal leads
2 x (2 x 0.75 mm
2
)
Conductor material
blank copper cl. 5 (DIN EN 60228; VDE 0295; IEC
60228)
Insulation
TEO Flexene ® polymer compound, compliant
with UL AWM & CSA AWM