beautypg.com

Drive technology – BECKHOFF AM3000 User Manual

Page 11

background image

Drive Technology

3 Safety

AM3000 / AM3500

Version: 1.5

11

3.2

Special safety instructions for AM3000 and AM3500

The safety instructions are designed to avert danger and must be followed during installation, commissioning,

production, troubleshooting, maintenance and trial or test assemblies.

The servomotors of the AM3000 and AM3500 series are not designed for stand-alone operation and are always

installed in a machine or system. After installation the additional documentation and safety instructions provided

by the machine manufacturer must be read and followed.

WARNING

Serious risk of injury through high electrical voltage!

Never open the servomotor when it is live. The measured voltage between terminals U, V

and W must have dropped below 50 V. Opening the device would invalidate any warranty

and liability claims against Beckhoff Automation GmbH & Co. KG.

Negligent, improper handling of the servomotor and bypassing of the safety devices can lead

to personal injury or death through electric shock.

Ensure that the protective conductor is connected properly.

The machine manufacturer must prepare a hazard analysis for the machine, and must take

appropriate measures to ensure that unexpected movements can not lead to injury to

persons or to material damage.

Power leads may be live, even if the motor is not running. Never undo the electrical

connections to the motor when it is live. Under unfavourable conditions arcing may occur,

resulting in injury and damage to contacts.

Disconnect the servomotor from the servo drive and secure it against reconnection before

working on electrical parts with a voltage > 50 V.

The DC link voltage of the servo drive may exceed 890 V. Wait until the DC link capacitors

are discharged before touching live terminals. The measured voltage between terminals DC+

and DC- (X02) must have dropped below 50 V.

WARNING

Serious risk of injury through hot surfaces!

The surface temperature may exceed 50 °C, resulting in a risk of burns.

Avoid touching the housing during or shortly after operation.

Leave the servomotor to cool down for at least 15 minutes after it is switched off.

Use a thermometer to check whether the surface has cooled down sufficiently.

Attention

Danger for persons, the environment or equipment

Carefully read this manual before using the servomotor thoroughly, paying particular

attention to the safety instructions. In the event of any uncertainties please notify your sales

office immediately and refrain from working on the servomotor.

Only well trained, qualified electricians with sound knowledge of drive equipment may work

on the device.

During installation it is essential to ensure that the specified ventilation clearances and

climatic conditions are adhered to. Further information can be found in the "Technical data"

and "Mechanical installation" sections.

If a servomotor is installed in a machine it must not be commissioned until proof of

compliance of the machine with the latest version of the EC Machinery Directive has been

provided. This includes all relevant harmonised standards and regulations required for

implementation of this Directive in national legislation.

This manual is related to the following products: