beautypg.com

Control of ip power 9212: set io – Aviosys 9212 Delux User Manual

Page 19

background image

- 18 -

2. When measuring the resistance of wet contacts, the maximum voltage is 5V and the maximum
currency is no more than 10mA。



Click the refresh button and you will see the similar figure like this. It represents the state of the
four sets of input signals (there may be some delay, it up to your network).

Control of IP Power 9212: SET IO


IP Power 9212 now can control 8 outputs at the same time.

* Out1 - Out4
are normally closed switches. When it is on, the corresponding LED lights up, the
circuit between the two connects is turn off.

When it is off, the corresponding LED light off, the circuit between the two connects is turn on.

* Out5 - Out8
are normally open switches. When it is on, the corresponding LED lights up, the
circuit between the two connects is turn on. When it is off, the corresponding LED light off, the
circuit between the two connects is turn off.