beautypg.com

9202 output pro hardware connection (recommend) – Aviosys 9212 Delux User Manual

Page 12

background image

IP POWER 9212 USER MANUAL

VER. 1.10

- 11 -

lower than

200Ω when it shows ON and higher than 500Ω when it shows OFF.

2. When measuring the resistance of web contacts, the maximum voltage is 5V and the
maximum currency is no more than 10mA。

PS: magnetic reed switch: using the magnetic field of the magnet to produce a signal when there

is a movement happened in switch. Low cost and easy to use is the chief characteristic of

magnetic reed switch. Most of them are used in security equipment, living product and automatic

mechanism.


9202 Output Pro Hardware connection (recommend)

IP Power 9202 Output Pro has predefined Relay Statuses.

Outputs 1 - 4:

Normal Closed Relay

(NC)

Outputs 5 - 8:

Normal Open Relay

(NO)

(The relay status of the outputs cannot be changed: Meaning that Output 1-4 will always

be

Normally closed

and Outputs 5-8 will always be

Normally Open

)



Maximum Rated Voltage: 240V/AC, 60V/DC
Maximum Rated Currency: 12A AC/DC
Maximum rated voltage for Single relay : 24V/ 10A , 120V/ 10A , 250/ 7A
Maximum Switch time: Max 10ms
Environment Temperature: -30°C~ + 55°C

NOTICE: Only the professionals should operate the following operations in this section

and the common user DO NOT try it!

For an example using a Light bulb

1.) Use the electrical wire of the equipment:

Step 1 : Cut off the live wire.(Use a test pencil or screwdriver with voltage tester to identify the

live wire between the two wires of electrical wire.)

NOTE:

For this method you must cut off the electrical wire of the household appliance. Please

make the decision after reading method 5-2 and 5-3.