beautypg.com

Howtorfid – Avery Dennison RFID User Manual

Page 21

background image

HowToRFID

Revision: 13

Date: 31 August 2009

Page 21 of 53

The following table provides the correlation between the numerical setting and the physical value for the EU
module (C1616, hardware Rev A 2.6HR1) and the US module (C1184, hardware Rev E).

C1616 – EU Module (Rev A 2.6HR1)

C1183 – US Module (Rev E)

Please note: range 0..30 dBm

Power dBm

Attenuation Value

0

255

1

253

2

251

3

248

4

246

5

245

6

243

7

241

8

240

9

238

10

236

11

234

12

232

13

231

14

230

15

227

16

223

17

221

18

218

19

213

20

208

21

204

22

199

23

190

24

182

25

170

26

160

27

140

28

110

29

70

Please note: range 18..30 dBm

Power dBm

Attenuation Value

18

255

19

230

20

200

21

160

22

140

23

110

24

90

25

70

26

55

27

40

28

25

29

10

30

0

Power Curve - AWID MPR 15xx EU, Rev A 2.6HR1, FW 4.07 I/Q4.06

-5

0

5

10

15

20

25

30

35

0

25

50

75

100

125

150

175

200

225

250

275

Power Setting (attenuation value)

P

o

w

e

r

O

u

tp

u

t

(d

B

m)

Measured Power

Power Curve - AWID MPR 1510-AE RM Rev E (FCC) , FW 2.33B I/Q4.11

0

5

10

15

20

25

30

35

0

25

50

75

100

125

150

175

200

225

250

275

Power Setting (attenuation value)

P

o

w

e

r

O

u

tp

u

t

(d

B

m

)

Measured Power

Table 8 – Power level to attenuation mapping tables

As visible from the table and charts above there are big differences in the range of adjustable power for the
EU/ETSI and US/FCC modules. So a power level setting (attenuation value) for the EU module can not be simply
transferred to the US module.