Howtorfid – Avery Dennison RFID User Manual
Page 21

HowToRFID
Revision: 13
Date: 31 August 2009
Page 21 of 53
The following table provides the correlation between the numerical setting and the physical value for the EU
module (C1616, hardware Rev A 2.6HR1) and the US module (C1184, hardware Rev E).
C1616 – EU Module (Rev A 2.6HR1)
C1183 – US Module (Rev E)
Please note: range 0..30 dBm
Power dBm
Attenuation Value
0
255
1
253
2
251
3
248
4
246
5
245
6
243
7
241
8
240
9
238
10
236
11
234
12
232
13
231
14
230
15
227
16
223
17
221
18
218
19
213
20
208
21
204
22
199
23
190
24
182
25
170
26
160
27
140
28
110
29
70
Please note: range 18..30 dBm
Power dBm
Attenuation Value
18
255
19
230
20
200
21
160
22
140
23
110
24
90
25
70
26
55
27
40
28
25
29
10
30
0
Power Curve - AWID MPR 15xx EU, Rev A 2.6HR1, FW 4.07 I/Q4.06
-5
0
5
10
15
20
25
30
35
0
25
50
75
100
125
150
175
200
225
250
275
Power Setting (attenuation value)
P
o
w
e
r
O
u
tp
u
t
(d
B
m)
Measured Power
Power Curve - AWID MPR 1510-AE RM Rev E (FCC) , FW 2.33B I/Q4.11
0
5
10
15
20
25
30
35
0
25
50
75
100
125
150
175
200
225
250
275
Power Setting (attenuation value)
P
o
w
e
r
O
u
tp
u
t
(d
B
m
)
Measured Power
Table 8 – Power level to attenuation mapping tables
As visible from the table and charts above there are big differences in the range of adjustable power for the
EU/ETSI and US/FCC modules. So a power level setting (attenuation value) for the EU module can not be simply
transferred to the US module.