beautypg.com

Avery Dennison 6037 Rev.AC 9/03 User Manual

Page 33

background image

Using Diagnostics

6-9

Paper Registration

Feeds and calibrates the printer’s supply.

1. Select Paper Reg.

Registration
Trigger to feed
ESC to Calibrate

2. Load the supply and feed it through the label path. Press

trigger to feed supply.

3. When stock has been loaded, press

b.

Stock Type:
2) Paper/Fax

4. Use l or r to select from Paper/Fax or Synthetic. Press

Enter. Two or three labels are fed (depending on the

supply position) and motor turns off. Sensors are now

calibrated to stock type.

NOTE: If the printer cannot calibrate, Error 704 is displayed. If

this error occurs, reload the supplies and recalibrate.

5. Press

b to return to the previous menu.

Status

Displays the printer’s current status.

1. Select Status.

Online, Active
Corr. Error
Stock Fault
B2=53 B3=42

2. Press

b or Enter to return to the previous menu.