Users Manual LOKPRINT™ II

Location / Power Requirements •••• 9

power. Because of the higher current draw of the LOKPRINT™ II, the printer /
Finishing Station or Cold Knife should be on a separate electrical service of 15A.
Refer to the Printer and Finishing Station or Cold Knife serial number plates for their
line requirements. Please check with your local electrical code and have the system
wired by a qualified electrician.

LOKPRINT™ II Main Line Protection

The LOKPRINT™ II main AC power switch also serves as a resettable circuit
breaker. The 115V machine incorporates a 20A breaker while the 230V machine
uses a 10A breaker.

LOKPRINT™ II Internal Fuse Configuration

Branch Circuit Protection

Both controllers and the feed motor drive circuit have a 5x 20mm fuse as per the
following chart.

Device

Fuse

Designator

AVERY

DENNISON Part #

115 VAC &

230VAC

U1

F3

990754

1.0A 250V FA

5x20mm

U2

F4

990754

1.0A 250V FA

5x20mm

Web
Feed

Motor

F6

990915

1.6A 250V TL

5x20mm