Argox F1 User Manual
Page 59
![background image](https://www.manualsdir.com/files/772017/content/doc059.png)
59
HEX DUMP
The hex dump mode is a troubleshooting tool
for checking the interconnection between the
printer and the host computer. Select “ON”
and all transmitted data is dumped and
printed as ASCII and Hex values.
OFF
Normal operating mode.
ON
Prints raw ASCII data received from the host.
SERIAL COMM.
Sets serial port communication.
Baud Rate
Determines the RS-232 baud rate.
9600bps
(1200~115200bps)
The default baud rate is 9600bps.
PARITY
The parity of the printer must match the parity
of the host computer for accurate
communications to take place.
None
No parity.
Odd
Odd parity.
Even
Even parity.
DATABITS
Set the Data Bit to match the setting used by
the host computer.
7Bits
Seven bit Word length.
8Bits
Eight bit Word length.
STOPBIT
Define Stop Bit.
1
One stop bit.
2
Two stop bits.
HANDSHAKE
Define handshake protocol between printer
and host.
BOTH
Use both handshaking methods.
XON/XOFF
CTS/RTS
FINE DARKNESS
Fine-tunes darkness based on current main
darkness level.
0 (-63~+63)
The default fine darkness is 0.
BASE SPEED
Sets the base print speed. The real print
speed is main speed plus base speed.