Calibration
Calibrating for Readback Accuracy

82

Operating Manual for XHR Series Power Supply

Output

Current

Monitor

Circuit

Calibration

1. Ensure that the power supply is turned OFF. Disconnect any load.
2. Connect the shunt and DVM across the power supply output to read the output

current.

3. Connect a second DVM to the rear panel J2 terminals 10 (output current

monitor) and 6 (program/monitor signal return). See notes below.

4. Turn the current control fully counter-clockwise, then turn ON the power supply.
5. Set the supply output current to 1% of its model-rated output. See note below.
6. Adjust the output current monitor offset potentiometer (R81) until the monitor

DVM indicates 1% of the readback scale. (50 mVdc for 0-5 V readback or
100 mVdc for 0-10 Vdc readback.)

7. Set the supply output current to the model-rated maximum output.
8. Adjust the output current monitor range potentiometer (R100) until the monitor

DVM reads 100% of the readback scale. (5 Vdc for 0-5 V readback or 10 Vdc
for 0-10 Vdc readback.)

Repeat this adjustment until the monitor scale is within the product specifications as
found in Section 1, or to the accuracy that your application requires.

Notes:

The recommended accuracy of the DVM and DC shunt-DVM combination is

four times better than your desired readback accuracy. The recommended

current ratings for the DC shunt and connecting wire is at least 10% greater than

the power supply's output current rating.

Depending on the readback accuracy required in your application, you may use

the front panel ammeter in place of the DC shunt-DVM combination.

Calculate the required output current reading using I = V/R where I is the

current, V is the DVM reading, and R is the DC shunt resistance.