Features and Specifications
Rear Panel Connectors and Switch

18

Operating Manual for XHR Series Power Supply

Rear Panel Connectors and Switch

The output terminals for the low voltage models (7.5 V to 40 V) are bus bars. The
high voltage models (60 V to 600 V) use a wire clamp connector. See Figure 1.2 and
Figure 1.3 to identify the switches and connectors on the rear panel.

Use the SW1 Programming, Monitoring, and Shutdown Select switch and the J2
Programming, Monitoring, and Sense connector to choose among several remote
programming and monitoring options. See the following sections for more
information about remote programming:

“SW1 Programming Switch” on page 19

“J2 Programming Connector” on page 20

Section 4. Remote Operation

Rear Panel

Illustrations

Figure 1.2 Rear Panel with Bus Bar

(For 7.5 V to 40 V models.)

100/120/200/240V

50/60 HZ

1300VA

AC Input Connector

(See page 36.)

SW1 Programming, Monitoring,

and Shutdown Select Switch

(See page 19.)

J2 Programming, Monitoring, and

Sense Connector

(See page 20 for more

information.)

Negative Output

(Return) Bus Bar

Fan Exhaust Vents

(Do not block.)

Positive Output Bus Bar

(See page 39.)

Blank Subplate

(Replaced if digital programming

interface installed.)

Ground Screw

Local Sense Wires

(See page 48.)