beautypg.com

Using the shutdown function, Standby switch – AMETEK XHR 1000 Watt Series User Manual

Page 61

background image

Local Operation

Using the Shutdown Function

61

Using the Shutdown Function

Use the Shutdown function to disable or enable the supply’s output so that you can
make adjustments to either the load or the power supply without shutting off the
entire supply. Activate this function from the front panel at any time by using the
STANDBY switch. You can also activate it via remote control through the rear panel
J2 connector, using a 2.5 V to 15 V signal or a transistor-transistor logic (TTL)
compatible input. The input lines for the Shutdown circuit are optically isolated.

STANDBY

Switch

The STANDBY switch is a press-button switch located on the power supply's front
panel. Pushing the switch to its IN position activates the Shutdown circuit. The
output voltage and current drop to zero and the S/D (shutdown) LED turns on.
Pushing the switch to its OUT position returns the power supply to normal operation.

Controlling

the Shutdown

Function via

the J2

Connector

The Shutdown circuit accepts a 2.5 V to 15 V signal to disable or enable the power
supply’s output. Make connections for signals at connector J2, located on the unit's
rear panel. Set rear panel switch SW1-7 to select signal logic. See Section 1 for more
information about making J2 connector or SW1 switch changes.

To activate the Shutdown function:

1. Turn the power supply OFF.
2. Connect the signal source to J2 connector terminal 11 (Shutdown Input/positive)

and terminal 12 (Shutdown Return).

3. Set switch SW1-7 to select the desired circuit logic as set out in

Table 3.2

.

4. Turn on the power supply.

The power supply will operate as described in

Table 3.2

according to the logic you

select and the level of the input signal you provide. The S/D LED on the front panel
turns on when the Shutdown circuit is activated.

Table 3.2 Switch Settings for Shutdown Circuit Logic

Note:If switch SW1-7 is set to ON but there is no signal applied, the S/D LED turns
on and the power supply will not provide an output until the HIGH signal level is
applied.

Switch SW1-7 Setting Source Signal Signal Level Supply Output

S/D LED

OFF (OPEN)
(Active low, default)

2-15 V

HIGH

OFF

ON

0-0.4 V

LOW

ON

OFF

ON (CLOSED)
(Active high)

2-15 V

HIGH

ON

OFF

0-0.4 V

LOW

OFF

ON