beautypg.com

Ac input power, Ac fail led, Ac input cord – AMETEK XHR 1000 Watt Series User Manual

Page 36: Ac input power” on

background image

Installation
AC Input Power

36

Operating Manual for XHR Series Power Supply

AC Input Power

We warrant that the unit will perform to specification at AC input voltage range from
85 to 250 Vac. The power output derates to 900 W when the AC input voltage is
below 95 V.

AC Fail LED

The AC Fail (ACF) LED turns on when the input voltage is outside

of the range specified for the power supply. The LED turns off when the input
voltage is within the range.

AC Input Cord

We ship the power supply with an AC input cord rated for your

location. See

Table 2.2

for the list of power cords that we ship. Use a power cord

rated for your local voltage as long as it is within the supply’s input range as stated
in “Input Conditions” on page 26. Any cord that you use requires a standard IEC 320
termination to mate with the power supply’s AC input connector. If you need a
specific cord, call us.

Table 2.2 Power Cords

WARNING
There is a potential shock hazard if the power supply chassis and cover are not
connected to an electrical ground via the safety ground in the AC input
connector. Ensure that the power supply is connected to a grounded AC outlet
with the recommended AC input connector configured for the available line
voltage

!

CAUTION
When the power switch is turned on, the output voltage or current previously set
will be applied to loads

Location

Power Cord Rating

North America

125 V, 13 A NA plug

Asia

125 V, 13 A NA plug

Great Britain

250 V, 10 A British plug