AMETEK XHR 1000 Watt Series User Manual
Xhr 1000 watt series programmable dc power supply
Table of contents
Document Outline
- warning
- 05.pdf
- Section 1. Features and Specifications
- 06.pdf
- Section 2. Installation
- Basic Setup Procedure
- Inspection, Cleaning, and Packing
- Initial Inspection
- Periodic Cleaning
- Returning Power Supplies to the Manufacturer
- Return Material Authorization Policy
- Packaging for Shipping or Storage
- Location, Mounting, and Ventilation
- Rack Mounting
- Ventilation
- AC Input Power
- AC Fail LED
- AC Input Cord
- Functional Tests
- Equipment Required
- Power-on Check
- Voltage Mode Operation Check
- Current Mode Operation Check
- Front Panel Function Check
- Load Connection
- Load Wiring
- Insulation Rating
- Current Capacity
- Load Wiring Length for Operation with Sense Lines
- Noise and Impedance Effects
- Making Load Connections
- Binding Posts (All Models)
- 7.5 V to 40 V Models
- Inductive Loads
- 60 V to 600 V Models
- Connecting Single Loads
- Connecting Multiple Loads
- Parallel Power Distribution
- Radial Power Distribution Method
- Load Wiring
- Local and Remote Sensing
- Sense Wiring
- Local Sensing
- Using Remote Sensing
- Section 2. Installation
- 07.pdf
- Section 3. Local Operation
- Standard Operation
- Operating Modes and Automatic Crossover
- Constant Voltage Mode Operation
- Constant Current Mode Operation
- Automatic Mode Crossover
- Shipped Configuration (Local Control Mode)
- Setting Output Voltage and Current Limit
- Operating Modes and Automatic Crossover
- Using Multiple Supplies
- Configuring Multiple Supplies for Series Operation
- Configuring Multiple Supplies for Parallel Operation
- Sensing for Parallel Operation
- Configuring Multiple Supplies for Split Supply Operation
- Two Positive Voltages
- Positive-negative Supply
- Using Over Voltage Protection (OVP)
- Front Panel OVP Operation
- Resetting the OVP Circuit
- Using the Shutdown Function
- STANDBY Switch
- Controlling the Shutdown Function via the J2 Connector
- Over Temperature Protection (OTP)
- User Diagnostics
- Emergency Shutdown
- Unusual or Erratic Operation
- Troubleshooting for Operators
- Abbreviated References Used in Table
- Standard Operation
- Section 3. Local Operation
- 08.pdf
- Section 4. Remote Operation
- Remote Analog Programming of Output Voltage and Current Limit
- Remote Programming Options
- Isolated Programming
- Remote Digital Programming
- Remote Analog Programming Procedure
- Sample Configuration
- Remote Programming Options
- Remote Monitoring of Output Voltage and Current
- Readback Signals
- Using the Isolated Programming (ISOL) Interface Option
- ISOL Specifications
- ISOL Setup and Operating Instructions
- ISOL Calibration
- Remote Analog Programming of Output Voltage and Current Limit
- Section 4. Remote Operation
- 09.pdf
- Section 5. Calibration
- Calibration Setup
- Service Environment and Precautions
- Equipment Required
- Front Panel Calibration
- Additional Setup
- Voltmeter Calibration
- Ammeter Calibration
- Over Voltage Protection (OVP) Calibration
- Calibrating for Programming Accuracy
- Voltage Programming Circuit Calibration
- Current Programming Circuit Calibration
- Calibrating for Readback Accuracy
- Output Voltage Monitor Circuit Calibration
- Output Current Monitor Circuit Calibration
- Calibration Setup
- Section 5. Calibration
- 06-section2.pdf
- Section 2. Installation
- 07-section3.pdf
- 08-section4.pdf
- 09-section5.pdf