beautypg.com

Resetting the switches, J2 programming connector – AMETEK XHR 1000 Watt Series User Manual

Page 20

background image

Features and Specifications
Rear Panel Connectors and Switch

20

Operating Manual for XHR Series Power Supply

See Table 1.1 for a list of the functions assigned to each SW1 switch.

Table 1.1 SW1 Switch Functions

Resetting the Switches

The rear panel is labelled with OFF at the top of the

switch and ON at the bottom. Any of the eight switches on SW1 is OFF (OPEN)
when it has been flipped up to break contact, ON (CLOSED) when flipped down to
close contact.

Before making any changes to the switch settings, disable the power supply output.
Either turn OFF the supply, or place the supply in shutdown mode by pressing the
front panel STANDBY button to its ON position. Once output is disabled, use any
small, straight-bladed screwdriver to change the switch settings.

J2

Programming

Connector

The J2 Programming, Monitoring, and Sense connector is a 12-terminal wire clamp
connector located on the power supply’s rear panel. The J2 connector provides
access to the following functions:

remote programming of output voltage and/or current limit

remote monitoring of calibrated readback signals for output voltage and output

current

remote control of the shutdown function using 2.5-15 V or TTL-compatible

signals

remote sensing of output voltage

Switch

Function

OFF (Open)

1

1. Factory defaults underlined.

ON (Closed)

1

SW1-1

1 mA current source for resistive
programming of output voltage.

Voltage source
programming

Resistive
programming

SW1-2

1 mA current source for resistive
programming of output current limit.

Voltage source
programming

Resistive
programming

SW1-3

Output voltage programming source
range select.

0-5 V

0-10 V

SW1-4

Output current limit programming
source range select.

0-5 V

0-10 V

SW1-5

Output voltage monitor range select.

0-10 V

0-5 V

SW1-6

Output current monitor range select.

0-10 V

0-5 V

SW1-7

Remote shutdown logic select.

HIGH=OFF

HIGH=ON

SW1-8

Over temperature shutdown reset
mode select.

Auto reset

Latch OFF