ANALOG REMOTE CONTROL (Single XEL-P models only)

Non-isolated inputs and outputs to set voltage and current limit

Control input and
output scaling:

Rear panel control inputs (CV and CC) permit external 0V to 5V or 0 to
10V signals to set 0 to 100% of rated output voltage and current.
Set values of 0 to 100% of rated output voltage and current generate
0 to 5V signals at the rear panel V

out

and I

out

outputs.

These signals are referenced to the positive output.

Control input
accuracy:

Voltage: 0.3% ±10mV. Input impedance 100k

Ω; protected to 60V.

Current: 0.5% ±5mA. Input impedance 64k

Ω; protected to 60V.

Control output
accuracy:

Voltage: 0.3% ±10mV
Current: 0.5% ±5mA.
Output impedance: 125

Ω; output short-circuit protected.

Remote Off:

Rear panel socket allows a switch closure or logic low to turn output off.

DIGITAL INTERFACES (XEL-P models only)
Full digital remote control facilities are available through the RS232,USB, LAN and GPIB interfaces

Voltage Setting:

Resolution 1mV, Accuracy ± (0·05% + 5mV)

Voltage Readback:

Resolution 1mV, Accuracy ± (0·1% + 5mV)

Current Setting and
Current Readback:

Resolution 0.1mA; 0.01mA on 500mA range.
Accuracy ± (0·3% + 3mA) to 3A, ± (0·5% + 3mA) to 6A;
± (0·3% + 0·3mA) on 500mA range.

RS232:

Standard 9-pin D-connector. Baud rate 9600.

GPIB (optional):

Conforming with IEEE488.1 and IEEE488.2

USB:

Standard USB 2.0 hardware connection. Operates as a virtual COM port.

LAN:

Ethernet 100/10base-T hardware connection. LXI V1.2, Class C
compliant.

Remote Command
Processing Time:

Typically <25ms between receiving the command terminator for a step
voltage change at the instrument and the output voltage beginning to
change.

GENERAL

AC Input:

230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II

Power Consumption:

Single: 280VA max. Dual: 560VA max.

Operating Range:

+5ºC to +40ºC, 20% to 80% RH

Storage Range:

−40ºC to + 70ºC

Environmental:

Indoor use at altitudes up to 2000m, Pollution Degree 2.

Cooling:

Intelligent variable-speed low noise fan assists convection. Over-
temperature trip shuts down output if internal temperatures exceed
predetermined thresholds.

Safety:

Complies with EN61010

−1

EMC:

Complies with EN61326

Size:

Single: 107mm x 131mm (¼ rack 3U) x 288mm L (XEL-P: 343mm L),

excluding feet, knobs and terminals.

Dual: 214mm x 131mm (½ rack 3U) x 288mm L, excluding feet, knobs
and

terminals.

Weight:

Single: 4·5kg (XEL-P: 4.9kg). Dual: 8.5kg.

7