Load Regulation:

For any load change, measured at the output terminals, using
remote sense:
Voltage <(0·01% + 2mV).
Add typically 2·5mV for a 0·5V drop in the positive output lead.
Specification applies for sense lead resistance <0·5

Ω.

Current typically <(0·01% + 500µA).

Line Regulation:

Voltage <(0·01% + 2mV) for 10% line change.
Current <(0·01% + 250µA) for 10% line change.

Temperature Coefficient:

Voltage: typically <(50ppm + 0·5mV)/°C
Current: typically <(100ppm + 1mA)/°C;

<(100ppm + 0·1mA)/°C on 500mA range.

Output Protection:

Output will withstand forward voltages of up to 20V above rated output
voltage. Reverse protection by diode clamp for currents up to 3A.

OTP Protection:

Output trips off for over-temperature.

OVP and OCP Protection:
(XEL-P models only)

Measure-and-compare over-voltage and over-current protection are
implemented in firmware and can be set via the remote interfaces only.
Output trips off for OVP and OCP. Setting resolution: 10mV and 1mA.
Response time: typically 500ms.
For manual operation (Local mode) OVP and OCP are fixed at 105% of
the instrument range maximum.

METER SPECIFICATIONS

Display Type:

Dual 4-digit meters, 10mm (0·39") LED.

Voltage: Resolution

10mV

Accuracy ± (0·1% of reading + 10mV)

Current:

Resolution 1mA; 0·1mA on 500mA range.
Accuracy ± (0·3% + 3mA) to 3A, ± (0·5% + 3mA) to 6A;
± (0·3% + 0·3mA) on 500mA range.

Current Meter Average:

Selects a 2s time constant (normally 20ms) for averaging of rapidly
varying load currents.

ADDITIONAL SPECIFICATIONS – XEL 30-3D QUAD-MODE DUAL

Independent Mode:

Each output is fully independent and isolated. Operation is equivalent to
two single power supplies.

Tracking Mode:

Tracking Accuracy:

The two outputs remain isolated but the Slave voltage controls are
disabled and the Slave voltage is set equal to the Master voltage.

Slave voltage = Master voltage ±(0.1% of Master voltage ±10mV).

Ratio (%) Tracking Mode:


Tracking Accuracy:

As tracking but the Slave voltage controls set an output voltage between
0% and 101% of the Master voltage. Once set, varying the Master voltage
will create the same percentage change in the Slave voltage setting.

% change in Slave voltage = % change of Master voltage ± 0.1% ±10mV.

Parallel Mode:

The Master output operates as a single output power supply with twice
the current capability (0.2mA to 6A). The Slave is disabled (and its
displays are turned off).

Both On / Both Off:

Each output has an independent DC On/Off control; these additional keys
can be used to turn both outputs on or off simultaneously. These keys
operate in all four modes.

6