beautypg.com

AMETEK XFR 2800 Watt Series User Manual

Page 95

background image

Electrical Specifications

TM-F2OP-C1XN-01

A-5

Temperature Coefficient:

h

Voltage (0.02% of Vmax/°C)
Current (0.03% of Imax/°C)

For Resistive Programming:

Voltage (0.06% of Vmax/°C)
Current (0.06% of Imax/°C)

12 mV
13.8 mA

36 mV
28 mA

20 mV
8.4 mA

60 mV
16.8 mA

30 mV
5.4 mA

90 mV
10.8 mA

60 mV
2.7 mA

180 mV
5.4 mA

120 mV
1.2 mA

360 mV
2.4 mA

OVP Adjustment Range:

(5% to 110% of Vmax)

3-66 V

5-110 V

7.5-165 V

15-330 V

30-660 V

Efficiency:

i

0.90

0.90

0.90

0.91

0.91

a.

Minimum output voltage is <0.15% of rated voltage at zero output setting.

b.

Minimum output current is <0.5% of rated current at zero output setting when measured at minimum 10% of full power
load.

c.

For input voltage variation over the AC input voltage range, with constant rated load.

d.

For 0-100% load variation, with constant nominal line voltage.

e.

Current mode noise is measured from 10% to 100% of rated output voltage, full current.

f.

Maximum drift over 30 minutes with constant line, load, and temperature, after power on.

g.

Maximum drift over 8 hours with constant line, load, and temperature, after 30-minute warm-up.

h.

Change in output per

°C change in ambient temperature, with constant line and load.

i.

Typical efficiency at nominal input voltage and full output power.

Table A-2 Specifications for 60 V to 600 V Models

Models

60-46

100-28

150-18

300-9

600-4