beautypg.com

Rear panel sw1 switch, Rear panel sw1 switch –6, Figure 1-3 – AMETEK XFR 2800 Watt Series User Manual

Page 24: Table 1-2

background image

Features and Specifications

1-6

TM-F2OP-C1XN-01

Rear Panel SW1 Switch

The SW1 Programming, Monitoring, and Shutdown Select switch is an
8-position piano DIP switch located on the power supply’s rear panel. See
Figure 1-3. The SW1 switch enables you to choose:

Resistive programming of output voltage or current limit

Output voltage and current limit programming scales

Output voltage and current monitor scales

Remote shutdown circuit logic

Over temperature shutdown mode

Table 1-2 shows the functions assigned to each SW1 switch.

Figure 1-3 Programming and Monitoring SW1 Switch

(Switch is shown in factory default configuration.)

1

Resistive Programming of Output Voltage

2

Resistive Programming of Output Current

3

Selects Output Voltage Programming Source Range

4

Selects Output Current Limit Programming Source Range

5

Selects Output Voltage Monitor Range

6

Selects Output Current Monitor Range

7

Selects Remote Shutdown Logic

8

Selects Over Temperature Shutdown Reset Mode

Table 1-2 Rear Panel SW1 Switch Assignments

Switch

Function

Open

a

a. Factory defaults underlined.

Closed

SW1-1

1 mA current source for resistive programming
of output voltage

Voltage source
programming

Resistive programming
(0-5 k, 0-10 k)

SW1-2

1 mA current source for resistive programming
of output current limit

Voltage source
programming

Resistive programming
(0-5 k, 0-10 k)

SW1-3

Output voltage programming source range select 0-5 V (0-5 k)

0-10 V (0-10 k)

SW1-4

Output current limit programming source range
select

0-5 V (0-5 k)

0-10 V (0-10 k)

SW1-5

Output voltage monitor range select

0-5 V

0-10 V

SW1-6

Output current monitor range select

0-5 V

0-10 V

SW1-7

Remote shutdown logic select

HIGH=OFF

HIGH=ON

SW1-8

Over temperature shutdown reset mode select

Auto reset

Latch OFF